SIMULATION OF AN ELECTROMYOGRAPHIC SIGNAL CONVERTER FOR ADAPTIVE ELECTRICAL STIMULATION TASKS

Authors

DOI:

https://doi.org/10.30837/ITSSI.2021.15.113

Keywords:

biopotential amplifier, useful signal, interference, muscle, electrode system, simulation, Multisim

Abstract

The subject matter of the article is an electromyographic signal transducer, which are an integral part of devices for adaptive electrical stimulation of muscle structures based on reverse electromyographic communication. The goal of the work is to study the features, obtaining the corresponding theoretical relationships and computer modeling of a differential biopotential converter, providing amplification of the useful component and suppression of harmful interference, the spectra of which intersect. The following tasks were solved in the article: determining the effect of electrode width and electrode spacing on crosstalk; formation of the electrode-skin model and the input circuit of the transducer, obtaining theoretical relations for calculating the rejection coefficient, construction of the transducer circuit and its computer simulation. The following methods were used – methods of mathematical modeling of processes and technical devices; methods of analysis, structural and parametric synthesis of nonlinear electronic circuits; methods of machine design. The following results were obtained – a biopotential amplifier circuit with tracking feedback on power supply is proposed; modeling of dynamic processes by means of the Multisim program was carried out; on the basis of the constructed model of the electrode-skin input circuit and the obtained analytical relationships, the rejection coefficient of the input circuit of the equivalent circuit is calculated; the requirements for the signal registration module are formulated. Conclusions: The considered version of the electromyographic signal converter circuit based on tracking communication on power supply, effectively rejects 50 Hz common mode noise. On the basis of the constructed equivalent model of the input circuit of the amplifier, the theoretical relation for calculating the rejection coefficient of such amplifiers. The circuit is simulated in the Multisim program, the results confirmed the correctness of its functioning. The requirements for the interelectrode distance and the thickness of the electrodes themselves are also formulated. The results obtained can be used to design complexes for adaptive electrical stimulation.

Author Biographies

Olha Yeroshenko, Kharkiv National University of Radio Electronics

Assistant Lecturer of the Department of Electronic Computers, PhD student of the Department of Biomedical Engineering

Igor Prasol, Kharkiv National University of Radio Electronics

Doctor of Sciences (Engineering), Associate Professor, Professor of the Department of Biomedical Engineering

Oleh Datsok, Kharkiv National University of Radio Electronics

PhD (Engineering Sciences), Associate Professor, Associate Professor of the Department of Biomedical Engineering

References

Voelkerб M. (2015), "Implantable EMG measuring system", AMA Conferences.

Pestrikovб P. P., Pestrikovaб T. V. (2019), "Measuring system for recording signals of surface electromyography of the muscles of the forearm" ["Izmeritel'naya sistema dlya registratsii signalov poverkhnostnoy elektromiografii myshts predplech'ya"], Electronic scientific publication "Scientific notes of PNU", Vol. 10, No. 2, P. 173–180.

Safinб D. R., Pilshchikovб I. S., Urakseevб M. A., Gusevб V. G. (2009), "Evaluation of the effectiveness of various designs of electrodes and biosignal amplifiers in prosthetic control systems" ["Otsenka effektivnosti razlichnykh konstruktsiy elektrodov i usiliteley biosignalov v sistemakh upravleniya protezami"], News of higher educational institutions. Volga region. Technical science, No. 2 (10), P. 88–101.

Datsok, O. M, Prasol, I. V., Yeroshenko, O. A. (2019), "Construction of a biotechnical system of muscular electrical stimulation", Visnik of NTU "KhPI". Series: Informatics and modeling, No. 13 (1338), P. 165–175. DOI: https://doi.org/10.20998/2411-0558.2019.13.15

Yeroshenko, O. A., Prasol, I. V., Datsok, O. M. (2019), "Improving the efficiency of devices for electrical stimulation of human muscles" ["Pidvyshchennya efektyvnosti funktsionuvannya aparativ dlya elektrostymulyatsiyi m'yaziv lyudyny"], Information technologies: science, technology, technology, education, health: abstracts of the XXVІІ international scientific-practical conference MicroCAD-2019, May 15-17, 2019 / for ed. prof. Sokol Ye. I., Kharkiv : NTU "KhPI", P. 21.

Yeroshenko, О. А., Prasol, I. V. (2018), "Information technologies for determining parameters of stimuli of electromyostimulation systems" ["Informatsionnyye tekhnologii opredeleniya parametrov stimulov sistem elektromiostimulyatsii"], The use of information technology in the training and operation of law enforcement: materials International. scientific-practical conf. Mar 14-15 2018, Kharkiv, NANGU, P. 122–124.

Barabash, O. V., Radchenko, V. A., Tkachev, V. N., Tokarev, V. V. (2017), "Computer multibiometric system of personality identification based on a set of biometric features" ["Komp'yuternaya mul'tibiometricheskaya sistema identifikatsii lichnosti po sovokupnosti biometricheskikh priznakov"], Telecommunication and information technologies, No. 3. P. 64–71.

Sushkova, O. S. (2017), A system for screening early diagnosis of parkinsonism based on the analysis of monitoring parameters of signals of multichannel electroencephalograms, electromyograms, and muscle tremor [Sistema skriningovoy ranney diagnostiki parkinsonizma na osnove analiza parametrov monitoringa signalov mnogokanal'nykh elektroentsefalogramm, elektromiogramm i myshechnogo tremora], Moscow, 114 p.

Slavutsky, Ya. L. (1982), Physiological aspects of bioelectric prosthesis management [Fiziologicheskiye aspekty bioelektricheskogo upravleniya protezami], Medicine, Moscow.

Kovalenko, A., Kuchuk, H., Lyashenko, О. (2019), "Resource allocation of a multiphase big data processing system with high-intensity input stream", Control, navigation and communication systems. Collection of scientific works, No. 3 (55), P. 115–119. DOI: https://doi.org/10.26906/SUNZ.2019.3.115

Luca, De C. J. (1997), "The use of surface electromyography in biomechanics", Journal of Applied Biomechanics, No. 13 (2).

Roy, S. H. (2007), "Electro-Mechanical stability of surface EMG sensors", Medical and biological engineering and computing, No. 45.

Osipov, A. N., Bondarik, V. M., Kuznetsov, D. F. (2014), "The influence of interelectrode distance on the energy characteristics of electromyograms" ["Vliyaniye mezhelektrodnogo rasstoyaniya na energeticheskiye kharakteristiki elektromiogramm"], International scientific and technical conference dedicated to the 50th anniversary of MRTI-BSUIR, March 18-19, 2014, materials conf. At 2 h. 2, Minsk, P. 115–116.

Babinkov, V. I. (2017), "To the question of the causes of the variability of the impedance of a contracting muscle during stimulation impedance myography" ["K voprosu o prichinakh variabel'nosti impedansa sokrashchayushcheysya myshtsy pri stimulyatsionnoy impedansnoy miografii"], Wounds and wound infections, Journal of them. prof. B. M. Kostyuchenka, No. 4 (3), P. 8–13.

Davydova, N. (2020), "Amplitude-time analysis of biomechanical patterns of human motions", Journal of Engineering Science, Vol. XXVII, No. 3, P. 169–181.

Analog Devices, Inc. All Rights Reserved, "AD620", available at: https://analog.com/media/en/technical-documentation/data-sheets/AD620.pdf (lastaccessed 11.05.2020).

Analog Devices, Inc. All Rights Reserved, "AD704", available at: https://analog.com/media/en/technical-documentation/data-sheets/AD704.pdf (lastaccessed 11.05.2020).

Downloads

Published

2021-03-31

How to Cite

Yeroshenko, O., Prasol, I., & Datsok, O. (2021). SIMULATION OF AN ELECTROMYOGRAPHIC SIGNAL CONVERTER FOR ADAPTIVE ELECTRICAL STIMULATION TASKS. INNOVATIVE TECHNOLOGIES AND SCIENTIFIC SOLUTIONS FOR INDUSTRIES, (1 (15), 113–119. https://doi.org/10.30837/ITSSI.2021.15.113