CLEARING THE ARGON OF OXYGEN BY THE METHOD OF LOW-TEMPERATURE RECTIFICATION IN AIR SEPARATIONS PLANTS AgKgKAArg-2
DOI:
https://doi.org/10.18198/j.ind.gases.2001.0013Keywords:
air separations units, argon, oxygen, hydrogen, low temperature rectification, clearing of argon of oxygenAbstract
The modern industry shows increased requirements to cleanliness of argon, and is especial to the contents in it of oxygen. In given article it is informed development and creation for the first time in domestic practice of the block rectifications clearing of argon Ar 0,1 intended for work with air separation unit AgKgKAArg 2 in which clearing of argon catalysis is usually provided by hydrogenation. Operation of block Ar 0,1 made by the Odessa joint-stock company «KISLORODMASH», within more than two years has confirmed its reliability and high quality of made argon.
Downloads
Issue
Section
License
LICENSE AGREEMENT
After receiving an article for publication as required revision scientometric databases each author directs the license agreement on the assignment and transfer of the management of copyright. Signatures of the author (s) it is desirable to seal the personnel department of the institution where the author works (authors), or the seal of the Faculty.
Revision refers to the authors one layout for proofreading. Permissible only those fixes that result in compliance with the layout of the original text of the article. Significant changes are not permitted. Layout should be sent to the editorial office within days of receipt.