COMPLEX INSPECTION AND REPAIR OF REGENERATORS OF AIR SEPARATION PLANTS «K-1,4» REGENERATORS
DOI:
https://doi.org/10.18198/j.ind.gases.2004.0152Keywords:
air separation plant, regenerators, inspection, repair, safety, acoustic-emissive controlAbstract
The defect of welded connections in regenerators’ cowlings was repeatedly shown in service of air separation plant «K-1,4» on JSC «Zlatoustovskiy metallurgical factory». The research of macro- and microstructures of the basic metal and welded seam have allowed to develop the technology of repair. For technical survey of the regenerator with the minimal man-hour the acoustic-emissive control was applied.
Downloads
Issue
Section
License
LICENSE AGREEMENT
After receiving an article for publication as required revision scientometric databases each author directs the license agreement on the assignment and transfer of the management of copyright. Signatures of the author (s) it is desirable to seal the personnel department of the institution where the author works (authors), or the seal of the Faculty.