ABOUT MAINTENANCE FIRE AND ECOLOGICAL SAFETY OF TANK CAPACITY WITH THE SULFUR PETROLEUM
DOI:
https://doi.org/10.18198/j.ind.gases.2012.0598Keywords:
Sour crude oil, Pyrophoric deposits, Nitrogen, Membrane nitrogen plants, SafetyAbstract
Storage of sour crude oil in steel tanks is increased fire and environmental hazard. The system allowing to create in oil treatment tanks of steam-nitrogen gas environment, excluding the self-ignition of pyrophoric deposits inside the tank is considered. The transformation of tanks at nitrogen «cushion» has led to a significant decrease as the corrosion rate and the rate of formation of pyrophoric deposits, but also affected on the structure of these deposits. The union trade tanks with a vapor-nitric environment by gas-equalization pipeline gave a significant reduction in emissions.
Downloads
Issue
Section
License
LICENSE AGREEMENT
After receiving an article for publication as required revision scientometric databases each author directs the license agreement on the assignment and transfer of the management of copyright. Signatures of the author (s) it is desirable to seal the personnel department of the institution where the author works (authors), or the seal of the Faculty.