STARTING CONDITIONS OF AIR SEPARATION PLANTS PROVIDED WITH ARGON PRODUCTION UNIT
DOI:
https://doi.org/10.18198/j.ind.gases.2012.0636Keywords:
Argon, Technical argon column, Starting conditions, Accumulation, Gaseous argon fractionAbstract
The starting conditions of the technical argon column included in the air separation plant (ASP) is described. The results of calculation of argon rectification over a wide range of parameters are presented. The conditions of argon accumulation in the liquid inside the technical argon column have been analyzed. Starting period duration — gaseous argon fraction argon content relationship for standard parameters of argon rectification units is shown, the comparison with actual data of operational ASPs is made. Recommended is the range of gaseous fraction composition for the technical argon column starting period, wherein the technical oxygen of the designed purity can be produced.
Downloads
Issue
Section
License
LICENSE AGREEMENT
After receiving an article for publication as required revision scientometric databases each author directs the license agreement on the assignment and transfer of the management of copyright. Signatures of the author (s) it is desirable to seal the personnel department of the institution where the author works (authors), or the seal of the Faculty.