Development of the Universal Air Collector Design for Measuring the Flow Rate of Swirling Air Flow Using an Integral Thermoanemometer
Abstract
Measurement of the swirling air flow rate and average speed of air at air distribution units of ventilation systems is a rather difficult task due to the fact that the air flow enters the measuring device at different angles. As a result, significant measurement errors can occur when using point thermoanemometers or other flow meters. The use of integral anemometers facilitates the measurement process. However, it is necessary to eliminate the errors associated with changes in the angle of the air flow to the sensing element of the measuring device. To do this, it is necessary to ensure a rectilinear structure of the air flow using a transitional air collector and rectifier. The aim of this paper is to develop a design of an air collector device that will allow to measure the flow rate of a swirling air flow. The objectives of the paper are to optimize the geometrical parameters of the air collector to ensure a rectilinear flow, minimize its dimensions and aerodynamic drag. The correctness of the air collector design was evaluated by matching the calibration characteristic of the probe of an integral thermoanemometer in the presence of a vortex diffuser in front of the air collector and in its absence. The proposed device has a rectangular shape and consists of a receiver, a rectifying grid, a chamber, an accelerating and stabilizing section, at the outlet of which a thermoanemometer probe is installed. The receiver and the accelerating section are tapered along their length, while the chamber and the stabilizing section have a constant cross-section. The rectifying grid is installed inside the chamber and has a square-shaped honeycomb structure. Several options of the air collector design with different geometrical parameters were studied using computer modelling. The dependence of aerodynamic drag on air flow was plotted. The optimal design of the air collector was chosen, for which a life-size physical model was created. The calibration characteristics of the measuring probe with an air collector were experimentally obtained when a swirling air flow was applied. The developed universal air collector allows the air flow rate measurement at the outlets of almost any air distribution devices of ventilation systems of buildings.
Downloads
Published
Issue
Section
License
Copyright (c) 2024 О. С. Цаканян, С. В. Кошель, Anna A. Kyryk
This work is licensed under a Creative Commons Attribution-NoDerivatives 4.0 International License.
All authors agree with the following conditions:
- The authors reserve the right to claim authorship of their work and transfer to the journal the right of first publication of the work under the license agreement (the agreement).
- Authors have a right to conclude independently additional agreement on non-exclusive spreading the work in the form in which it was published by the jpurnal (for example, to place the work in institution repository or to publish as a part of a monograph), providing a link to the first publication of the work in this journal.
- Journal policy allows authors to place the manuscript in the Internet (for example, in the institution repository or on a personal web sites) both before its submission to the editorial board and during its editorial processing, as this ensures the productive scientific discussion and impact positively on the efficiency and dynamics of citation of published work (see The Effect of Open Access).