System-structural cycles analysis of refrigerating machines and heat pump installations
Keywords:
heat pump installation, refrigerating machine, criterion of the complexity, exergetic lossAbstract
On the basis of modern methods of applied thermodynamics method of system-structural analysis of the thermodynamic efficiency of refrigerating machines (RM) and heat pump systems (HP) been designed. To assess the impact of the structural complexity of the technological scheme of heat pump installations on its thermodynamic perfection the first time in the thermodynamic analysis of the criterion of the complexity of the scheme been introduced.By using the proposed method at the stage of the design analysis RM and HP depending on the structural complexity of the technological scheme the rational design characteristics of the heat exchange surface of the evaporator and condenser, piping of basic equipment can choose.Systemic laws of appearance of losses of irreversibility in the technological scheme of refrigeration and heat pump systems vapor compression type been identified.
References
Brodyanskyy, V.M., Fratsher V., Myhalek K. (1988). Ekserhetycheskiy metod i ego prilogenij - M.: Energoatomizdat, 288 c.
Taubman, EI. (1983). Analis and syntes of teplotehnycheskyh system. Energoatomizdat, 1983, 176 c.
Boer, D. (2005). Exergy and structural analysis of an absorption cooling cycle and the effect of efficiency parameters. Intern. J. Thermodynamics. Vol. 8 (4), P. 191–198.
Bratuta, E.G., Kharlampidi, D. Kh, Sherstuk, A.V. (2006). Vlijanie neyzobarnosty procesa condensatii i isparenia na energetycheskye pocazateli holodylnih machin i teplovih nasosov. Vostoch. Evrope. Zh. peredovih technology, №3 / 3 (21), C. 91–93.
Bratuta, E.G., Sherstuk, A.V., Kharlampidi, D. Kh. (2007). Analysis soprotivlenia soedinitelnih trudoprovodov holodilnih mashin na ee efectivnost. Integrovani technologii i energosberegenie, № 1, С. 16−23.
Kim, Y. J., Park, I. S. (2000). Development of Performance-Analysis Program for Vapor-Compression Cycle based on Thermodynamic Analysis. J. Industrial and Engin. Chemistry, Vol. 6 (6), P. 385–394.
Kalaiselvam, S., Saravanan, R. Exergy analysis of scroll compressors working with R22, R407C, and R417 as refrigerant for HVAC system. Thermal Scien. Vol. 13, P. 175–184.
Downloads
Published
Issue
Section
License
Copyright (c) 2016 Д. Х. Харлампиди
This work is licensed under a Creative Commons Attribution-NoDerivatives 4.0 International License.
All authors agree with the following conditions:
- The authors reserve the right to claim authorship of their work and transfer to the journal the right of first publication of the work under the license agreement (the agreement).
- Authors have a right to conclude independently additional agreement on non-exclusive spreading the work in the form in which it was published by the jpurnal (for example, to place the work in institution repository or to publish as a part of a monograph), providing a link to the first publication of the work in this journal.
- Journal policy allows authors to place the manuscript in the Internet (for example, in the institution repository or on a personal web sites) both before its submission to the editorial board and during its editorial processing, as this ensures the productive scientific discussion and impact positively on the efficiency and dynamics of citation of published work (see The Effect of Open Access).