CALCULATION OF MULTISTREAM HEAT EXCHANGERS BY NONLINEAR SWEEP METHOD
DOI:
https://doi.org/10.18198/j.ind.gases.2008.0348Keywords:
Multistream counter-flow heat exchanger, Calculation, A sweep method, Expe-rience of application, Problems in application, Iteration, Convergence of decisions, Under-recuperationAbstract
The sweep method widely used in a thermal conduction problems, is applied for calculation of the multistream counter-flow heat exchanger in which are some direct and some inverse streams. In this case the problem of boundary conditions is mathematical and thermodynamic solved. Nonlinear correlations of coefficients are solved by organization of iterative procedure. The method is applied to the heat exchanger with 11 streams. Results of tempe-rature field calculations give a great volume of information for an analysis of the solutions accepted at projection. It is shown as not optimum distribution of streams in 2…3 times worsens thermal performances of the heat exchanger. Merits and demerits of application of a sweep method surveyed. Problems of the method application for the heat exchangers with two-phase streams are emphasized. Comparison to alternative methods is carried out.
Downloads
Issue
Section
License
LICENSE AGREEMENT
After receiving an article for publication as required revision scientometric databases each author directs the license agreement on the assignment and transfer of the management of copyright. Signatures of the author (s) it is desirable to seal the personnel department of the institution where the author works (authors), or the seal of the Faculty.
Revision refers to the authors one layout for proofreading. Permissible only those fixes that result in compliance with the layout of the original text of the article. Significant changes are not permitted. Layout should be sent to the editorial office within days of receipt.