Evaluation of acoustic signal features in children with community-acquired pneumonia and pneumonia caused by the SARS-CoV-2 virus using the new acoustic monitoring device "Trembita-Corona"

Authors

DOI:

https://doi.org/10.15587/2519-4798.2023.283687

Keywords:

acoustic monitoring, diagnostics, , community-acquired pneumonia, COVID-19, SARS-CoV-2

Abstract

Early diagnosing pneumonia caused by the SARS-CoV-2 virus is an urgent problem today. The diagnosis of pneumonia caused by the SARS-CoV-2 virus is difficult, which is why it is promising to use acoustic monitoring to speed up the diagnosis and start of therapy.

Aim: to determine the features of acoustic diagnostics of children with pneumonia caused by the SARS-CoV-2 virus using the "Trembita-Corona" acoustic monitoring device to correct and supplement traditional diagnostic methods. That is why respiratory acoustics is currently a promising scientific direction. We, pediatric specialists from Ukraine and leading specialists of the National Aviation University (Ukraine), have developed an experimental sample of the "Trembita-Corona" acoustic monitoring device. This device is used to diagnose breathing sounds. A patent protects the main constructive technical solutions of this device.

Methods. We studied 230 patients aged 1 month to 18 years. The children were divided into 3 groups: 1 group – 100 patients with САР (the PCR test for the determination of the SARS-CoV-2 virus is negative), 2 group -100 healthy children(the PCR test for the determination of the SARS-CoV-2 virus is negative), 3 group - 30 children with pneumonia caused by the SARS-CoV-2 virus the PCR test for the determination of the SARS-CoV-2 virus is positive).

The study complied with the international principles of GCP, GLP for clinical research. The protocol was approved at the meeting of the Commission on Bioethical Expertise at the National Medical University, named after O.O. Bogomolets. Mathematical processing was performed on specialized software developed in the Python language in the Google Codelabs environment. Further statistical processing of the obtained results was performed in specialized programs Medstart, EZR (R-Statistics) and "Matlab".

Results. We use the "Trembita-Corona" acoustic monitoring device to analyze sounds at different octaves. In each of the 11 octaves using the "Trembita-Corona" acoustic monitoring device, we investigated the following indicators: the average signal power, frequency of the acoustic signal and amplitude.

Using the аcoustic monitoring device "Trembita-Corona", were found differences between children with САP and healthy ones in average signal power in 0,1,2,3,4,5,6 octaves, in the frequency of the acoustic signal in 0 and 5 octaves, and in the amplitude of the acoustic signal in 0,2,3,4,5,6 octaves. Differences between children with САP and children with pneumonia caused by the SARS-CoV-2 virus in terms of average signal power in 0,1,2,3,4,5,6,7,9 octaves, frequency of the acoustic signal in 0 and 5 octaves, and amplitude of the acoustic signal in 0,1,4,5,6 octaves were also analyzed.

Differences in average signal power and amplitude of the acoustic signal between pneumonia caused by the SARS-CoV-2 virus and healthy children were determined in the 2nd octave (p<0.01). Also, differences between these groups were found in the amplitude of the acoustic signal in the 8th octave.

Conclusion. The "Trembita-Corona" acoustic monitoring device is a new and promising acoustic method for determining the location of a pathological process in the lungs. Characteristic differences were found in the average signal power and amplitude of the acoustic signal between pneumonia caused by the SARS-CoV-2 virus and healthy children (p<0.01) in the 2nd octave and in the amplitude of the acoustic signal in the 8th octave

Author Biographies

Olha Khomych, Bogomolets National Medical University

Assistant

Department of Pediatrics Postgraduate Education

Yuriy Marushko, Bogomolets National Medical University

Doctor of Medical Sciences, Professor

Department of Pediatrics Postgraduate Education

References

  1. de Benedictis, F. M., Kerem, E., Chang, A. B., Colin, A. A., Zar, H. J., Bush, A. (2020). Complicated pneumonia in children. The Lancet, 396 (10253), 786–798. doi: https://doi.org/10.1016/s0140-6736(20)31550-6
  2. Klinichna nastanova, zasnovana na dokazakh «Pnevmonii u ditei» (2022). Nastanova No. KN 2022-1380. 02.08.2022. Available at: https://www.dec.gov.ua/?ZG93bmxvYWQ=d3AtY29udGVudC91cGxvYWRzLzIwMjIvMDgvMjAyMl8xMzgwX2tuX3BuZXZtb25peWlfdV9kaXRlai5wZGY=
  3. Standarty medychnoi dopomohy «Pozalikarniani pnevmonii u ditei» (2022). Nakaz MOZ Ukrainy No. 1380. 02.08.2022. Available at: https://ліки.укр/admin/upload/file/NPA%20and%20projects/38989-dn_1380_02_08_2022.pdf
  4. Yun, K. W., Wallihan, R., Juergensen, A., Mejias, A., Ramilo, O. (2019). Community-Acquired Pneumonia in Children: Myths and Facts. American Journal of Perinatology, 36 (S 02), S54–S57. doi: https://doi.org/10.1055/s-0039-1691801
  5. Marushko, Y. V., Khomych, O. V., Hyshchak, T. V., Tarynska, O. L., Shchegel, G. O. (2021). State of the art usage of radiological and acoustic methods for the diagnosis of pneumonia, including those caused by SARS-CoV-2 virus, in children. Review. Medical Science of Ukraine (MSU), 17 (2), 114–124. doi: https://doi.org/10.32345/2664-4738.2.2021.16
  6. le Roux, D. M., Zar, H. J. (2017). Community-acquired pneumonia in children – a changing spectrum of disease. Pediatric Radiology, 47 (11), 1392–1398. doi: https://doi.org/10.1007/s00247-017-3827-8
  7. Marushko, Y., Khomych, O. (2023). Frequency characteristics of acoustic features of sound signals in the lungs of children with pneumonia using a new acoustic diagnostic device “Trembita-Corona.” Neonatology, Surgery and Perinatal Medicine, 12 (4 (46)), 59–66. doi: https://doi.org/10.24061/2413-4260.xii.4.46.2022.9
  8. Marushko, Yu., Khomych, O. (2023). Characterization of the average power, frequency and amplitude of acoustic signal peaks over the lungs in children with community-acquired pneumonia using the new device “Trembita-Corona.” Medical Science of Ukraine (MSU), 19 (1), 53–69. doi: https://doi.org/10.32345/2664-4738.1.2023.08
  9. Isaienko, V., Kharchenko, V., Astanin, V., Shchegel, G., Olefir, V., Olefir, O. et al. (2020). System for acoustic diagnostics and symptomatic assistance to covid-19 patients for use in extremal conditions "Trembita-Coronа NAU". Proceedings of the National Aviation University, 82 (1), 58–63. doi: https://doi.org/10.18372/2306-1472.82.14612
  10. Marushko, Yu. V., Khomych, O. V. (2023). Assessment of acoustic signal characteristics in children with community-acquired pneumonia according to the prevalence and nature of lung tissue damage using the new device «Trembita-Corona». Modern Pediatrics. Ukraine, 2 (130), 79–88.
  11. Pavlenko, P. M., Marushko, Yu. V., Olefir, O. I., Khomych, O. V., Shchehel, H. O., Khomych, V. M., Olefir, A. O. (2021). Pat. No. 148836 UA. Prystrii akustychnoho sposterezhennia iz osovoiu diahramoiu napravlenosti. MKP G10K 11/08 (2006.01), G10K 11/28 (2006.01), G01V 1/46 (2006.01), G01S 11/14 (2006.01). No. u202102140. declareted: 23.04.2021; published: 22.09.2021, Bul. No. 38.
  12. Rao, A., Huynh, E., Royston, T. J., Kornblith, A., Roy, S. (2019). Acoustic Methods for Pulmonary Diagnosis. IEEE Reviews in Biomedical Engineering, 12, 221–239. doi: https://doi.org/10.1109/rbme.2018.2874353

Downloads

Published

2023-03-31

How to Cite

Khomych, O., & Marushko, Y. (2023). Evaluation of acoustic signal features in children with community-acquired pneumonia and pneumonia caused by the SARS-CoV-2 virus using the new acoustic monitoring device &quot;Trembita-Corona&quot;. ScienceRise: Medical Science, (2(53), 31–37. https://doi.org/10.15587/2519-4798.2023.283687

Issue

Section

Medical Science