Analysis of strength and deformativity of glass plate joints under static loading

Authors

DOI:

https://doi.org/10.15587/2706-5448.2020.202735

Keywords:

glass layers, triplex, prototype, glass plates, elements junction node

Abstract

The weak point of any structure is always the elements junction node. This article presents the results of a study of the adhesion of glass plates interconnected over the entire surface by means of adhesive materials and triplex technology under the action of static loading. The bearing capacity and deformability of such joints was established. For the research purposes there were designed, manufactured and tested 6 series of prototypes. Thus, the object of the study is 6 series of test specimens for testing the adhesion of glass plates to each other. The prototypes consisted of three glass plates, each 10 mm thick, interconnected by means of triplex technology and various adhesive materials. Before bonding, the glass plates of the prototypes of I–V series were cleaned of dirt and degreased. The adhesive was applied to the entire surface of one plate. Then, the glass plates were firmly interconnected with the help of the vise and held for 5–10 minutes. The curing time depended on the adhesive materials. The curing of the glue of the prototypes of the fourth and fifth series was done under the rays of an ultraviolet lamp. The plates of the sixth series prototypes were interconnected by triplex technology, where EVASAFE polymer film (Bridgestone, Japan) was inserted between the plates and the prototypes were heated to 130 ºC and held for 30 minutes.

An experimental research program was developed. The test rig consisted of a stand for static structural strength tests. The external load N was applied by means of a hydraulic jack and was performed step by step. The magnitude of the load was 1.0 kN and was monitored using dynamometer for the I–V series prototypes and a ring dynamometer for the VI series prototypes until the complete destruction of the prototype. At each load stage a 10 minutes exposure was performed followed by gauge reading.

On the basis of the obtained results, an analysis of glass plates adhesion was performed and an averaged dependency graph of shear deformations and tangent stresses τ=N/A for the series of the prototypes was constructed. This provides the ability to obtain strengths and deformations for a series of prototypes.

Author Biographies

Mykhailo Surmai, Lviv Polytechnic National University, 12, Stepana Bandery str., Lviv, Ukraine, 79013

PhD, Senior Lecturer

Department of Building Structures and Bridges

Roman Tkach, Lviv Polytechnic National University, 12, Stepana Bandery str., Lviv, Ukraine, 79013

Postgraduate Student

Department of Building Structures and Bridges

References

  1. Del Linz, P., Hooper, P. A., Arora, H., Smith, D., Pascoe, L., Cormie, D. et. al. (2015). Reaction forces of laminated glass windows subject to blast loads. Composite Structures, 131, 193–206. doi: http://doi.org/10.1016/j.compstruct.2015.04.050
  2. Zubkov, V., Kondratieva, N. (2008). Characteristics of calculation of flat glass in translucent structures. Glass performance days 2008. New Delhi, 27–29.
  3. Kislyuk, Ya., Shmigel, R., Savenko, V., Sukhoosov, G. (2010). Efficiency of application of gluing metal joints of elements of wooden constructions. New technologies in construction, 1 (19), 75–78.
  4. Demchyna, B., Surmai, M., Tkach, R. (2018). Еxperimental research of laminated glass column for central compresson. Bulletin of the National University of Lviv Polytechnic: Theory and Practice of Construction, 888, 52–58.
  5. Demchyna, B. H., Surmai, M. I., Tkach, R. O. (2018). Pat. No. 128990 UA. Skliana korona. MPK: Е04С 3/30, Е04В 1/18, Е04В 1/28, Е04Н 15/34, Е04Н 15-60. No. u201805969; declareted: 29.05.2018; published: 10.10.2018. Bul. No. 19.
  6. Demchyna, B. H., Surmai, M. I., Tkach, R. O., Osadchuk, T. Yu. (2019). Pat. No. 140007 UA. Zrazok dlia vyprobuvan zcheplennia plastyn mizh soboiu. MPK: G01N 3/08. No. u201905744; declareted: 27.05.2019.
  7. Kalamar, R., Eliasova, M. (2015). Load Bearing Innovative Construction from Glass. 2nd International Conference on Innovative Materials, Structures and Technologies. Riga, 1–7. doi: http://doi.org/10.1088/1757-899x/96/1/012066
  8. Petersen, R., Bagger, A. (2019). Structural use of glass: Cruciform columns and glass portals with bolted connections subjected to bending. Glass performance days 2009, 371–375.
  9. Campione, G., Di Paola, M., Minafò, G. (2014). Laminated Glass Members in Compression: Experiments and Modeling. Journal of Structural Engineering, 140 (2), 04013047. doi: http://doi.org/10.1061/(asce)st.1943-541x.0000827
  10. Hyatt, P., Hyatt, J. (2004). Great Glass Buildings: 50 Modern Classics. Images Publishing, 240.

Published

2020-03-05

How to Cite

Surmai, M., & Tkach, R. (2020). Analysis of strength and deformativity of glass plate joints under static loading. Technology Audit and Production Reserves, 2(1(52), 38–41. https://doi.org/10.15587/2706-5448.2020.202735

Issue

Section

Reports on research projects