Analysis of dual-flow plates with a large free section

Authors

DOI:

https://doi.org/10.15587/2706-5448.2020.208493

Keywords:

dual-flow plate, large free section of the column, hydraulic resistance, height of the gas-liquid layer.

Abstract

The object of research is the dual-type plates with a large free section. One of the most problematic areas of such plates is their low efficiency, which depends on the operating mode of the dual-type plates with a large free section. The gas-liquid layer on such plates is represented by drops and films of liquid, which are the dispersed phase. In this case, the continuous phase is gas. Insufficient liquid supply on dual-flow plates with a large free section leads to a decrease in the efficiency of such plates.

During the research, the method of hydrodynamic modeling was used. This method consists in the fact that the dual-flow plates are investigated first in experimental installations, and their results, according to a certain method, are used to calculate industrial plates.

A study of dual-flow plates with a large free section in a wide range of gas and liquid loads has been carried out. The range of work of the plates has been determined. It has been established that the hydraulic resistance of the dual-flow plates with a large free section depends little on the diameter of the column apparatus. An almost complete coincidence of the dependence of the height of the gas-liquid layer on the gas velocity in the column cross-section is shown for dual-flow plates with a large free section installed in columns with diameters D=0.057, 0.4 and 2 m. It is revealed that a column with a diameter of D=0.057 m can be used to simulate the operation of dual-flow plates with a large free section of industrial diameter. For example, for dual-flow plates of the usual free section during hydrodynamic modeling, it is necessary to use pilot plants with columns of larger diameter D=0.15–0.25 m with a large free cross-section can operate at significantly higher gas and liquid velocities compared to the dual-flow plates with a conventional free cross-section.

The use of dual-flow plates with a large free section is recommended in absorption processes at high irrigation densities.

Author Biography

Gennadiy Taranenko, Volodymyr Dahl East Ukrainian National University, 59-a, Tsentralnyi ave., Severodonetsk, Ukraine, 93400

PhD, Associate Professor

Department of Mechanical Engineering and Equipment Industry

References

  1. Syeda, S. R., Afacan, A., Chuang, K. T. (2007). A Fundamental Model for Prediction of Sieve Tray Efficiency. Chemical Engineering Research and Design, 85 (2), 269–277. doi: http://doi.org/10.1205/cherd06111
  2. Bubble Tray Design Manual (1958). New York: American Institute of Chemical Engineers, 94.
  3. Chan, H., Fair, J. R. (1984). Prediction of point efficiencies on sieve trays. 1. Binary systems. Industrial & Engineering Chemistry Process Design and Development, 23 (4), 814–819. doi: http://doi.org/10.1021/i200027a032
  4. Chen, G. X., Chuang, K. T. (1993). Prediction of point efficiency for sieve trays in distillation. Industrial & Engineering Chemistry Research, 32 (4), 701–708. doi: http://doi.org/10.1021/ie00016a017
  5. Diener, D. A. (1967). Calculation of Effect of Vapor Mixing on Tray Efficiency. Industrial & Engineering Chemistry Process Design and Development, 6 (4), 499–503. doi: http://doi.org/10.1021/i260024a018
  6. Gerster, J. A., Hill, A. B., Hochgraf, N. N., Robinson, D. G. (1958). Tray Efficiencies In Distillation Columns Аmerican Institute of Chemical Engineers (AIChE). Final report from the University of Delaware. New York, 118.
  7. Bennett, D. L., Agrawal, R., Cook, P. J. (1983). New pressure drop correlation for sieve tray distillation columns. AIChE Journal, 29 (3), 434–442. doi: http://doi.org/10.1002/aic.690290313
  8. Mukhlenov, I. P., Tarat, E. IA., Tubolkin, A. F., Tumarkina, E. S. (1977). Pennii rezhim i pennye apparaty. Leningrad: Khimiia, 304.
  9. Taranenko, G. V. (2019). Gas content on dual-flow plate in a combined contact device. ScienceRice, 1 (54), 19–25. doi: http://doi.org/10.15587/2313-8416.2019.155858
  10. Taranenko, G. V. (2013). Gidravlicheskie i massoobmennye kharakteristiki tarelok provalnogo tipa s razlichnym diametrom otverstii. Lugansk: VNU im. V. Dalia, 174.
  11. Taranenko, G. V. (1984). Gidrodinamika i massoperedacha kombinirovannogo kontaktnogo ustroistva. GIAP, 298.