Analyzing test results of infusion pumps
DOI:
https://doi.org/10.15587/2312-8372.2014.21331Keywords:
infusion pump, speed of solution delivery, measuring error, solution volumeAbstract
The analysis of results of testing infusion pumps, which can be used in resuscitation and delivery rooms of intensive care, in other hospital rooms and when transporting patients, including ambulance cars has been proposed. The differences between actual and given volumes of an injecting solution and speed of its delivery were found. The principles of estimating data accuracy of infusion pumps complying with the international standards were considered. The experimental studies of an infusion pump for checking its operational data reliability were carried out. The calculations by the formulas complying with international standards were made. The prerequisites for developing a risk prediction model when operating infusion pumps were developed. The analysis of the International Electrotechnical Commission standard IEC 60601-1-8 was carried out. Medical electrical equipment Part 1-8: General requirements for basic safety and essential performance – Collateral standard: General requirements, tests and guidance for alarm systems in medical electrical equipment and medical electrical systems.References
- Интенсивная терапия. Реанимация. Первая помощь [Текст] / под ред. В.Д. Малышева. – М.: Медицина, 2000. – 464 с. – ISBN 5–225–04560-Х.
- Инфузионный насос [Электронный ресурс]. – Режим доступа: www/URL: http://ru.wikipedia.org/wiki/Инфузионный_насос#cite_ref-1
- Agres, T. FDA Seeking Safer Infusion Pumps [Text]/ T. Agres // Pharmacy Practice News. – May 2010. – Vol. 37, №5. – P. 4.
- International Standard IEC 60601-2-24. Medical electrical equipment part 2-24: Particular requirements for the safety of infusion pumps and controllers [Text]. – First Edition 1998–02. – Geneva: International electrotechnical commission, 2012. – 63 p. – ISBN–2–8318–4265–4.
- Инфузионный насос. Описание изобретения к патенту [Текст]: RU 2325957 C2. – Опубликовано:10.06.2008. – Бюл.16. – Санкт-Петербург: Федеральная служба по интеллектуальной собственности, патентам тa товарным знакам: СПб.: МЕДАКС АБ(SE). – 11 с.
- International Standard IEC 60601-1-8. Medical electrical equipment part 1-8: General requirements for basic safety and essential performance – Collateral standard: General requirements, tests and guidance for alarm systems [Text]. – Edition 2.1 2012–11. – Geneva: International electrotechnical commission, 2012. – 187 p. – ISBN–978–2–8322–0492–4.
- Landi, A. Backpropagation-Based Non Linear PCA for Biomedical Applications [Text]/ A. Landi, P. Piaggi, G. Pioggia// Intelligent Systems Design and Applications. – 2009. – №2. – Р. 635-640.
- Хаїмзон, І. І. Медичні знання та прийняття рішень в медицині [Текст]/ І. І. Хаїмзон, А. Т. Теренчук. – Вінниця: ВНТУ, 2007. – 180 с.
- ДСТУ ISO 14971:2009. Вироби медичні. Настанови щодо управління ризиком [Текст]. – (ISO 14971:2007, IDT): введ.2012-01-01. – Київ: Держспоживстандарт; ДП «УкрНДНЦ», 2012. – 61 с.
- Ripley, B. D. Statistical aspects of neural networks [Text]/ B. D. Ripley. – London: Published by Chapman & Hall, 1994. – Р. 40-111.
- In: Malyshev, V. D. (2000). Intensivnaia terapiia. Reanimatsiia. Pervaia pomoshch'. M.: Meditsina, 464. ISBN 5–225–04560-X.
- Infuzionnyi nasos. Available: http://ru.wikipedia.org/wiki/Infuzionnyi _nasos#cite_ref-1
- Agres, T. (May 2010). FDA Seeking Safer Infusion Pumps. Pharmacy Practice News, Vol. 37, №5, 4.
- International Standard IEC 60601-2-24. (2012). Medical electrical equipment part 2-24: Particular requirements for the safety of infusion pumps and controllers. Ed. 1: 1998–02. Geneva: International electrotechnical commission, 63. ISBN–2–8318–4265–4.
- Infuzionnyi nasos. Opisanie izobreteniia k patentu: RU 2325957 C2. (10.06.2008). Biul.16. Sankt-Peterburh: Federal'naia sluzhba po intellektual'noi sobstvennosti, patentam ta tovarnym znakam: SPb.: MEDAKS AB(SE), 11.
- International Standard IEC 60601-1-8. (2012). Medical electrical equipment part 1-8: General requirements for basic safety and essential performance – Collateral standard: General requirements, tests and guidance for alarm systems. Ed. 2.1: 2012–11. Geneva: International electrotechnical commission, 187. ISBN–978–2–8322–0492–4.
- Landi, A., Piaggi, P., Pioggia, G. (2009). Backpropagation-Based Non Linear PCA for Biomedical Applications. Intelligent Systems Design and Applications, №2, 635-640.
- Khaimzon, І. І., Terenchuk, A. T. (2007). Medichnі znannia ta priiniattia rіshen' v meditsinі. Vіnnitsia: VNTU, 180.
- DSTU ISO 14971:2009. (2012). Virobi medichnі. Nastanovi shchodo upravlіnnia rizikom. Kiiv: Derzhspozhivstandart; DP «UkrNDNTs», 61.
- Ripley, B. D. (1994). Statistical aspects of neural networks. London: Published by Chapman & Hall, 40-111.
Downloads
Published
How to Cite
Issue
Section
License
Copyright (c) 2016 Михайло Юрійович Буриченко, Марина Володимирівна Дворнік, Ольга Борисівна Іванець
This work is licensed under a Creative Commons Attribution 4.0 International License.
The consolidation and conditions for the transfer of copyright (identification of authorship) is carried out in the License Agreement. In particular, the authors reserve the right to the authorship of their manuscript and transfer the first publication of this work to the journal under the terms of the Creative Commons CC BY license. At the same time, they have the right to conclude on their own additional agreements concerning the non-exclusive distribution of the work in the form in which it was published by this journal, but provided that the link to the first publication of the article in this journal is preserved.