Ignition detection method based on real-time measurements of a hazardous parameter in the environment
DOI:
https://doi.org/10.15587/1729-4061.2024.306709Keywords:
detection of fires, selective average, dangerous parameters, gas environment, ignition of materialAbstract
The object of this study is a selective average of the dangerous parameters of the gas environment during the ignition of materials. Theoretical substantiation of the fire detection method based on testing the null hypothesis regarding the current difference of the specified selective averages of an arbitrary dangerous parameter of the gas environment has been performed. In this case, the significance of the current difference with respect to selective averages allows detection of ignition in real-time observation of an arbitrary dangerous parameter of the gas environment. The method makes it possible to set the level of significance for the current difference and at the same time provide for the maximum power of fire detection. Laboratory experiments were conducted to verify the proposed method for detecting ignition based on the current difference of the selective averages of the measured dangerous parameters of the gas environment corresponding to the training and control general population. The results of verification showed that at a given level of significance, the method allows detecting current fires of materials based on significant differences in sample means. It was established that the current difference in the concentration of carbon monoxide during ignition and after ignition of alcohol, paper, wood shavings, and textiles is –0.459 and 8.296, –0.152 and 4.299, –0.027 and 6.9, –0.262 and 2.3, respectively. Current smoke density differences are 0.043 and 0.391, 0.012, and 0.923, –0.139, and –0.235, 0.034, and 0.129, and temperatures are –0.01 and 10.635, 0.53 135 and 2.726, respectively. This means that the current difference is significant and is due not to a random nature but to the appearance of a persistent effect from the ignition of the material. In practice, research results can be used to detect fires in real time in order to prevent them from growing into an uncontrolled fire
References
- Popov, O., Kovach, V., Iatsyshyn, A., Lahoiko, A., Ryzhchenko, O., Dement, M. (2023). Features Function of Radiation Monitoring System World’s Countries of Developed Nuclear Energy. Systems, Decision and Control in Energy V, 471–497. https://doi.org/10.1007/978-3-031-35088-7_25
- Center of Fire Statistics (2022). World Fire Statistics of CTIF, 27.
- Fonollosa, J., Solórzano, A., Marco, S. (2018). Chemical Sensor Systems and Associated Algorithms for Fire Detection: A Review. Sensors, 18 (2), 553. https://doi.org/10.3390/s18020553
- Pospelov, B., Rybka, E., Savchenko, A., Dashkovska, O., Harbuz, S., Naden, E. et al. (2022). Peculiarities of amplitude spectra of the third order for the early detection of indoor fires. Eastern-European Journal of Enterprise Technologies, 5 (10 (119)), 49–56. https://doi.org/10.15587/1729-4061.2022.265781
- Wu, Y., Harada, T. (2004). Study on the Burning Behaviour of Plantation Wood. Scientia Silvae Sinicae, 40 (2), 131–136. https://doi.org/10.11707/j.1001-7488.20040223
- Çetin, A. E., Dimitropoulos, K., Gouverneur, B., Grammalidis, N., Günay, O., Habiboǧlu, Y. H. et al. (2013). Video fire detection – Review. Digital Signal Processing, 23 (6), 1827–1843. https://doi.org/10.1016/j.dsp.2013.07.003
- Gaur, A., Singh, A., Kumar, A., Kulkarni, K. S., Lala, S., Kapoor, K. et al. (2019). Fire Sensing Technologies: A Review. IEEE Sensors Journal, 19 (9), 3191–3202. https://doi.org/10.1109/jsen.2019.2894665
- Wen, Z., Xie, L., Feng, H., Tan, Y. (2019). Robust fusion algorithm based on RBF neural network with TS fuzzy model and its application to infrared flame detection problem. Applied Soft Computing, 76, 251–264. https://doi.org/10.1016/j.asoc.2018.12.019
- Geetha, S., Abhishek, C. S., Akshayanat, C. S. (2020). Machine Vision Based Fire Detection Techniques: A Survey. Fire Technology, 57 (2), 591–623. https://doi.org/10.1007/s10694-020-01064-z
- Pospelov, B., Andronov, V., Rybka, E., Bezuhla, Y., Liashevska, O., Butenko, T. et al. (2022). Empirical cumulative distribution function of the characteristic sign of the gas environment during fire. Eastern-European Journal of Enterprise Technologies, 4 (10 (118)), 60–66. https://doi.org/10.15587/1729-4061.2022.263194
- Pospelov, B., Rybka, E., Samoilov, M., Morozov, I., Bezuhla, Y., Butenko, T. et al. (2022). Defining the features of amplitude and phase spectra of dangerous factors of gas medium during the ignition of materials in the premises. Eastern-European Journal of Enterprise Technologies, 2 (10 (116)), 57–65. https://doi.org/10.15587/1729-4061.2022.254500
- Pospelov, B., Andronov, V., Rybka, E., Chubko, L., Bezuhla, Y., Gordiichuk, S. et al. (2023). Revealing the peculiarities of average bicoherence of frequencies in the spectra of dangerous parameters of the gas environment during fire. Eastern-European Journal of Enterprise Technologies, 1 (10 (121)), 46–54. https://doi.org/10.15587/1729-4061.2023.272949
- Popov, O., Iatsyshyn, A., Kovach, V., Iatsyshyn, A., Neklonskyi, I., Zakora, A. (2023). Is There a Future for Small Modular Reactors in Ukraine? Comparative Analysis with Large Capacity Reactors. Systems, Decision and Control in Energy V, 453–469. https://doi.org/10.1007/978-3-031-35088-7_24
- Sadkovyi, V., Andronov, V., Semkiv, O., Kovalov, A., Rybka, E., Otrosh, Yu. et al.; Sadkovyi, V., Rybka, E., Otrosh, Yu. (Eds.) (2021). Fire resistance of reinforced concrete and steel structures. Kharkiv: РС ТЕСHNOLOGY СЕNTЕR, 180. https://doi.org/10.15587/978-617-7319-43-5
- Lehmann, E. L. (Ed.) (1999). Elements of Large-Sample Theory. Springer Texts in Statistics. https://doi.org/10.1007/b98855
- Levin, B. R. (1966). Teoreticheskie osnovy statisticheskoy radiotehniki. Moscow: Sovetskoe radio.
- Cramér, H. (1999). Mathematical methods of statistics. Princeton University Press, 575.
- Sadkovyi, V., Pospelov, B., Rybka, E., Kreminskyi, B., Yashchenko, O., Bezuhla, Y. et al. (2022). Development of a method for assessing the reliability of fire detection in premises. Eastern-European Journal of Enterprise Technologies, 3 (10 (117)), 56–62. https://doi.org/10.15587/1729-4061.2022.259493
- Pospelov, B., Rybka, E., Krainiukov, O., Yashchenko, O., Bezuhla, Y., Bielai, S. et al. (2021). Short-term forecast of fire in the premises based on modification of the Brown’s zero-order model. Eastern-European Journal of Enterprise Technologies, 4 (10 (112)), 52–58. https://doi.org/10.15587/1729-4061.2021.238555
- Otrosh, Y., Rybka, Y., Danilin, O., Zhuravskyi, M. (2019). Assessment of the technical state and the possibility of its control for the further safe operation of building structures of mining facilities. E3S Web of Conferences, 123, 01012. https://doi.org/10.1051/e3sconf/201912301012
Downloads
Published
How to Cite
Issue
Section
License
Copyright (c) 2024 Boris Pospelov, Olekcii Krainiukov, Yuliia Bezuhla, Olena Petukhova, Andrii Melnychenko, Oleg Bogatov, Serhii Holovchenko, Oleksandr Nepsha, Olha Yesipova, Kateryna Tishechkina
This work is licensed under a Creative Commons Attribution 4.0 International License.
The consolidation and conditions for the transfer of copyright (identification of authorship) is carried out in the License Agreement. In particular, the authors reserve the right to the authorship of their manuscript and transfer the first publication of this work to the journal under the terms of the Creative Commons CC BY license. At the same time, they have the right to conclude on their own additional agreements concerning the non-exclusive distribution of the work in the form in which it was published by this journal, but provided that the link to the first publication of the article in this journal is preserved.
A license agreement is a document in which the author warrants that he/she owns all copyright for the work (manuscript, article, etc.).
The authors, signing the License Agreement with TECHNOLOGY CENTER PC, have all rights to the further use of their work, provided that they link to our edition in which the work was published.
According to the terms of the License Agreement, the Publisher TECHNOLOGY CENTER PC does not take away your copyrights and receives permission from the authors to use and dissemination of the publication through the world's scientific resources (own electronic resources, scientometric databases, repositories, libraries, etc.).
In the absence of a signed License Agreement or in the absence of this agreement of identifiers allowing to identify the identity of the author, the editors have no right to work with the manuscript.
It is important to remember that there is another type of agreement between authors and publishers – when copyright is transferred from the authors to the publisher. In this case, the authors lose ownership of their work and may not use it in any way.