Development of methods for the gas chromatogrphic determination of the content of dissolved components in the energy oils

Authors

  • Сергей Владимирович Зайцев Оdesa National Politechnic University, Shevchenko av. 1, Оdesa, Ukraine, 65044, Ukraine
  • Виктор Афанасьевич Кишневский Оdesa National Politechnic University, Shevchenko av. 1, Оdesa, Ukraine, 65044, Ukraine
  • Святослав Лаврентьевич Савич Оdesa National Politechnic University, Shevchenko av. 1, Оdesa, Ukraine, 65044, Ukraine

DOI:

https://doi.org/10.15587/1729-4061.2014.29389

Keywords:

gas chromatography, extraction, energy oil, ionol, dissolved gas, furan compound

Abstract

The paper presents the results of the development of methods for the gas chromatographic determination of the content of dissolved components: gases (H2, CH4, C2H6, C2H4, C2H2, CO, CO2, C3H8, C3H6, H2S); ionol; furan compounds (furfural; acetylfuran; 5-methyl-furfural; 2-furan-methanol) in the energy oils (transformer, cable, condenser, turbine). The purpose of the paper was to reduce the errors of measurement methods and improve the accuracy of measurement results in determining the content of dissolved components in the energy oils by the static version of the extraction-gas chromatographic measurements using gas chromatographic analysis of equilibrium phases - gaseous or liquid extracts. For modern energy oils, the values of the distribution coefficients in the system "energy oil - dissolved gas - gas-extractant" using static and dynamic variants of extraction-gas chromatographic measurements were defined; formulas for calculating the concentrations of ionol and furan compounds in the energy oils based on accepted mathematical models of extraction processes for measurements were obtained; optimum procedures of extraction-gas chromatographic determination of the content of dissolved gases, ionol and furan compounds in the energy oils for developing optimal gas scheme of multichannel gas chromatograph were selected. The conditions for implementing the extraction-gas chromatographic measurements using appropriate adsorbents in packed chromatographic columns in determining the content of: dissolved gases - by the absolute calibration using the distribution coefficients for these gases instead of the corresponding Ostwald coefficients; ionol or furan compounds - by adding corresponding pure component or various extractant volumes in the energy oils. In the presence of emulsion water in the energy oil, oil is dried by silica gel (in determining ionol) or sodium sulfate (in determining furan compounds. The results of the calculations are assessed). It was found that it is necessary to perform temperature programing of the corresponding chromatographic column after the evolution of the chromatographic peak of the last determined component. The developed techniques can be used in determining the concentrations of dissolved components in the energy oils for technical diagnostics of oil-filled electrical equipment; quality indicators of the energy oils; compatibility of mixed energy oils and sensitivity of these oils to ionol.

Author Biographies

Сергей Владимирович Зайцев, Оdesa National Politechnic University, Shevchenko av. 1, Оdesa, Ukraine, 65044

Engineer

Department of Water Technology and Fuel

Виктор Афанасьевич Кишневский, Оdesa National Politechnic University, Shevchenko av. 1, Оdesa, Ukraine, 65044

Professor

Department of Water Technology and Fuel

Святослав Лаврентьевич Савич, Оdesa National Politechnic University, Shevchenko av. 1, Оdesa, Ukraine, 65044

Associate Professor

Department of Technology of Inorganic Substances and Environmental

References

  1. SOU-N ITS 46.302:2006 Preparation and implementation of the chromatographic analysis of gases selected from Buchholz, and gases dissolved in insulating oil oil-filled electrical equipment. Methodical instructions (2007). Kiev: PEP: "GRIFRE", 70.
  2. SOU-N ITS 43.101: 2009 Acceptance, use and operation of transformer oils. Standards of Quality Assessment (2009). Kiev: KVITS: Ministry of Energy of Ukraine, 152.
  3. SOU-N ITS 46.501:2006 (2007). Diagnosis oil-filled transformer equipment on the results of the chromatographic anali free gases selected from gazovoo relay, and gases dissolved in insulating oil. Methodical instructions. Kiev PEP: "GRIFRE", 92.
  4. Treybal, R. E. (1963). Liguid Extraction. Second edition. New York, 720.
  5. Hachenberg, H., Schmidt, А. Р. (1977). Gas Cromatographic Head space Analysis. – New York, Rheine, Heyden, 126.
  6. Liilewood, A. B. (1970). Gas Cromatography. Second edition. New York. Academic Press, 456.
  7. Pugh, P. S., Wagner, H. H. (1961). Detection of Incipient Faults in Transformers by Gas Analysis. Transactions of the American Institute of Electrical Engineers. Part III: Power Apparatus and Systems, 80 (3), 189–193. doi: 10.1109/aieepas.1961.4501008
  8. Guide for the sampling of gases and of oil from oil-filled electrical equipment and the analysis of free and dissolved gases (2005). IEC publication 60567:1992-07. Geneva, Switzerland, 80.
  9. Ferreto, S. J. (1990). A comparative study of dissolved gas analysis techniques: the vacuum extraction method versus the direct inectijn method // IEEE Transaction on Power Delivery, 5 (1), 220–225. doi: 10.1109/61.107324
  10. Torkos, K., Borossey, J., Szekely, А. (1984). Determination of fault gases in transformers oils. Journal of Chromatography, 286, 317–321. doi: 10.1016/s0021-9673(01)99201-5
  11. Leblanc, Y. Gilbert, R., Duval, М., Hubert, J. (1993). Static headspace gas chromatographic determination of fault gases dissolved in transformer insulating oils // Journal of Chromatography, 633 (1-2), 185–193. doi: 10.1016/0021-9673(93)83153-j
  12. Duval, М. (2003). New techniques for dissolved gas-oil analysis // IEEE Electrical Insulation Magazine, 19 (2), 6–15. doi: 10.1109/mei.2003.1192031
  13. Ioffe, B. V., Kostkina, M. I., Wittenberg, A. G. (1980). The distribution coefficients and solubility of gases in transformer oil. Journal of Applied Chemistry, 10, 2280–2285.
  14. ASTM Standard D 4768-96. Standard Test Method for Analysis of 2,6-Ditertiary-Butyl Para-Cresol and 2,6-Ditertiary-Butyl Phenol in Insulating Liquids by Gas Chromatography (1996). ASTM International, 3.
  15. Neustroeva, I. V. (2005). Guidelines for the preparation and holding of the chromatographic analysis apрarat-software complex "Chromatec Crystal". Transformer oil. Determination of antioxidant additives ionol. SKB "Chromatec", Yoshkar-Ola, 33.
  16. Buzaev, V. V., Livov, Y. N., Smolenskaya, N. Y., Saposhnichov, Y. M. (1996). Gas chromatographic analysis of transformer oil content of air, water and ionol / Collection of articles. Methods and tools to assess the state of the power equipment. Issue 2. Petersbugsky Energy Institute for Advanced Studies; Ministry of Energy. St. Petersburg, 88–90.
  17. Zaitsev, S. V., Bolshakov, D. A., Jankowski, G. K. (2010). Determination of ionol in transformer oil by gas-liquid chromatography with a thermal conductivity detector // Electrical networks and systems, 1, 58–64.
  18. Mosevа, E. V., Srednitskaya, N. I., Kolodko, T. M. (2000). Definition ionol in industrial oils // Abstracts of the Mezhdunarnoy scientific conference. Resource-Environmental Technology: renewal and saving energy, raw materials and materials. Grodno, 145–146.
  19. Zaitsev, S. V. Kishnevsky, V. A., Gulyaenko, B. A. (2013). Gas chromatographic determination of the distribution coefficients in the "transformer oil – ionol – extractant" // Proceedings of Odessa Polytechnic University, 3 (42), 86–90.
  20. Emsley, A. M., Xiao, Х., Heywood, R. J., Ali, М. (2001). Degradation of cellulose insulation in power transformers. Pt. 3. Effects of oxygen and water on ageing in oil // IEEE. Proc. Sci., Meas. and Technol, 147 (3), 115–110. doi: 10.1049/ip-smt:20000021
  21. Oomen, T. V., Breemen, van R. B. (1993). Analysis of furanic compounds from cellulose aging by GS – MS attemps to correlate with degree polymerization. CIGRE Symposium on Diagnostic and Maintenance techniques, Berlin, 110–112.
  22. Mineral insulating oils. Method for the determination of 2-furfural and related compounds (1993). IEC publication 61198:1993-09. Geneva, Switzerland, 28.
  23. Neustroeva, I. V. (2005). Guidelines for the preparation and holding of the chromatographic analysis apрarat-software complex "Chromatec Crystal". Transformer oil. Determination of furan derivatives in transformer oil / SKB "Chromatec", Yoshkar-Ola, 36.
  24. Zaitsev, S. V., Kishnevsky, V. A. (2013). Gas chromatographic method for determination of dissolved in transformer oil components // Proceedings of Odessa Polytechnic University, 2 (41), 132–137.
  25. Wittenberg, A. G., Joffe, B. V. (1982). Gas chromatographic analysis to extraction. Head space analysis and related methods. Lviv: Chemistry, 280.

Published

2014-12-11

How to Cite

Зайцев, С. В., Кишневский, В. А., & Савич, С. Л. (2014). Development of methods for the gas chromatogrphic determination of the content of dissolved components in the energy oils. Eastern-European Journal of Enterprise Technologies, 6(6(72), 34–42. https://doi.org/10.15587/1729-4061.2014.29389

Issue

Section

Technology organic and inorganic substances