Experimental researching of biological objects noninvasive passive acoustothermometry features
DOI:
https://doi.org/10.15587/1729-4061.2020.192594Keywords:
ultrasound, acoustothermometry, internal temperature, piezoelectric transducer, acoustic thermometer, thermal acoustic radiation.Abstract
Experimental confirmation of the possibility of real-time measurement of the internal (deep) temperature of a biological object by thermal acoustic radiation with an accuracy of at least 0.2 °C using an acoustic thermometer implementing the modified zero modulation method is obtained. The model of a single-channel passive noninvasive focussed acoustic thermometer based on a plate piezoceramic electro-acoustic transducer, acoustic elliptical lens and blocks of two serial voltmeters is developed. Electronic switching of the output signals of the noise simulator and the equivalent circuit of the focused piezoelectric transducer is proposed, when resistance generates thermal noise with an intensity equal to the sum of intensities of acoustic radiation of the biological object and natural noise of the piezoelectric transducer. This circuitry solution made it possible to exclude the mechanical modulator (shutter) unit used in analogs from the acoustic thermometer circuit. When developing the original switching and detection unit, it was proposed to use the key mode of n-channel field-effect transistors to perform modulation of the input noise signal. Calculation of equivalent circuits of the piezoelectric electroacoustic transducer and noise simulator, which are connected circuits with a bandwidth in which the average noise voltage level is determined by the noise voltage at the electric resonance frequency of the piezoelectric element, is performed. The possibility of using the model of the single-channel passive noninvasive focussed acoustic thermometer, constructed according to the circuit implementing the modified zero modulation method, for measuring noise voltages in the range from 5 to 30 μV is proved. Since the process of manufacturing or operating a piezoceramic electroacoustic transducer may lead to a deviation of its parameters from theoretically calculated, a method is developed to measure the frequency response of the active and reactive components of electrical impedance. Using the proposed method, the assembly quality of the focused piezoelectric electro-acoustic transducer is monitored and the temperature dependence of electric noise voltage at the electrodes of the focused piezoelectric receiver is obtained.
References
- Naida, S. A. (2002). Acoustothermometry of liquid objects using priezoelectronic receivers of megahertz range. Tehnicheskaya diagnostika i nerazrushayushchiy kontrol', 3, 41–48.
- Bowen, Т. (1987). Acoustic radiation temperature for noninvasive thermometry. Automedica (UK), 8 (4), 247–267.
- Anosov, A. A., Kazansky, A. S., Subochev, P. V., Mansfel’d, A. D., Klinshov, V. V. (2015). Passive estimation of internal temperatures making use of broadband ultrasound radiated by the body. The Journal of the Acoustical Society of America, 137 (4), 1667–1674. doi: https://doi.org/10.1121/1.4915483
- Anosov, A. A., Sharakshane, A. A., Kazanskii, A. S., Mansfel’d, A. D., Sanin, A. G., Sharakshane, A. S. (2016). Instrument function of a broadband acoustic thermometric detector. Acoustical Physics, 62 (5), 626–632. doi: https://doi.org/10.1134/s1063771016050018
- Anosov, A. A., Belyaev, R. V., Klin’shov, V. V., Mansfel’d, A. D., Subochev, P. V. (2016). Passive broadband acoustic thermometry. Technical Physics, 61 (4), 597–602. doi: https://doi.org/10.1134/s1063784216040058
- Anosov, A. A., Subochev, P. V., Mansfeld, A. D., Sharakshane, A. A. (2018). Physical and computer-based modeling in internal temperature reconstruction by the method of passive acoustic thermometry. Ultrasonics, 82, 336–344. doi: https://doi.org/10.1016/j.ultras.2017.09.015
- Drozdenko, E. S., Naida, S. A. (2009). O vliyanii detektirovaniya shuma na tochnost' izmereniya temperatury akustotermometrom. Elektronika i svyaz', 6, 62–67.
- Naida, S. A., Drozdenko, K. S. (2012). The modified scheme of deep temperature measurement zero modulation method. Systemy obrobky informatsiyi, 5, 47–52.
- Drozdenko, K. S. (2013). Single-channel focusable acoustothermometer for measuring the internal temperature of biological object. Radioelectronics and Communications Systems, 56 (4), 207–211. doi: https://doi.org/10.3103/s0735272713040067
- Agarwal, A., Lang, J. (2005). Foundations of Analog and Digital Electronic Circuits. Morgan Kaufmann Publishers is an imprint of Elsevier, 1008.
- Bakshi, U. A., Godse, A. P. (2009). Analog And Digital Electronics. Technical Publications, 547.
- Kino, G. S. (1987). Acoustic waves: Devices, imaging, and analog signal processing. Prentice Hall, 601.
- Beranek, L. L., Mellow, T. J. (2012). Acoustics: Sound Fields and Transducers. Academic Press, 720.
- Preobrazovateli, antenny gidroakusticheskie. Metodiki izmereniya parametrov na ispytatel'nyh bazah predpriyatiya: RD 5.0542-86 (1990). Kyiv: Minsudprom.
Downloads
Published
How to Cite
Issue
Section
License
Copyright (c) 2020 Vitalii Didkovskyi, Sergey Naida, Oleksandr Drozdenko, Kateryna Drozdenko
This work is licensed under a Creative Commons Attribution 4.0 International License.
The consolidation and conditions for the transfer of copyright (identification of authorship) is carried out in the License Agreement. In particular, the authors reserve the right to the authorship of their manuscript and transfer the first publication of this work to the journal under the terms of the Creative Commons CC BY license. At the same time, they have the right to conclude on their own additional agreements concerning the non-exclusive distribution of the work in the form in which it was published by this journal, but provided that the link to the first publication of the article in this journal is preserved.
A license agreement is a document in which the author warrants that he/she owns all copyright for the work (manuscript, article, etc.).
The authors, signing the License Agreement with TECHNOLOGY CENTER PC, have all rights to the further use of their work, provided that they link to our edition in which the work was published.
According to the terms of the License Agreement, the Publisher TECHNOLOGY CENTER PC does not take away your copyrights and receives permission from the authors to use and dissemination of the publication through the world's scientific resources (own electronic resources, scientometric databases, repositories, libraries, etc.).
In the absence of a signed License Agreement or in the absence of this agreement of identifiers allowing to identify the identity of the author, the editors have no right to work with the manuscript.
It is important to remember that there is another type of agreement between authors and publishers – when copyright is transferred from the authors to the publisher. In this case, the authors lose ownership of their work and may not use it in any way.