Determination of optimal transient in the anti-surge control system of the gas compressor unit

Authors

  • Георгій Никифорович Семенцов Ivano-Frankivsk National Technical University of Oil and Gas Karpatska 15, Ivano-Frankivsk, Ukraine, 76019, Ukraine https://orcid.org/0000-0001-8976-4557
  • Андрій Іванович Лагойда Ivano-Frankivsk National Technical University of Oil and Gas Karpatska 15, Ivano-Frankivsk, Ukraine, 76019, Ukraine https://orcid.org/0000-0002-0862-7786

DOI:

https://doi.org/10.15587/1729-4061.2014.27793

Keywords:

centrifugal supercharger, surge, performance, anti-surge control, optimal transient

Abstract

The paper examines the problem of determining the optimal transient in the anti-surge control system of the gas compressor unit with gas turbine drive on the example of the C-6.3 type centrifugal supercharger. The problem of determining the switching points, constructing the optimal transient was considered. A method to improve the anti-surge control system performance in conditions of the booster compressor station of underground gas storage was proposed since performance of anti-surge control system of the gas compressor unit is a key factor to improve the booster compressor station reliability.

The defined optimal transient in the anti-surge control system of the gas compressor unit with gas turbine drive and transient time show that they significantly differ from the transient in the system for the case when nonoptimal control action is supplied to the control object input.

Author Biographies

Георгій Никифорович Семенцов, Ivano-Frankivsk National Technical University of Oil and Gas Karpatska 15, Ivano-Frankivsk, Ukraine, 76019

Professor

Department of process automation and monitoring environmental

Андрій Іванович Лагойда, Ivano-Frankivsk National Technical University of Oil and Gas Karpatska 15, Ivano-Frankivsk, Ukraine, 76019

Graduate student

Department of process automation and monitoring environmental 

References

  1. 1. Fabri, I. (1967). Rotating stale inaxial flow compressors. Internal Aerodynamics, Institution of Mechanical Engineers. (Conference Cambridge. Session 5: Unsteady flow effects, Paper 9), 96–110.

    2. Gеorgants, A. (1994). Review of compressor Aerodynamic Instabilies. National Aeronautical Establishment, Canada, 125–134.

    3. Sparks, C. R. (1983). On the transient in tradition of centrifugal compressors and their piping systems. Trens of the ASME. Journal of Engineering for power, 891–901. doi: 10.1115/1.3227498

    4. Gerasimenko, V. P. (2001). To improve the sustainability of natural gas systems with compressor. Avіats. kosm.tehnіka i tehnologіya, 23–45.

    5. Gіrenko, S. G. (2008). Method avtomatizovanogo Zahist compressors dotiskuvalnoї kompresornoї stantsії pіdzemnogo skhovischa gas surge od. Oil and Gas energy, 1 (6), 43–47.

    6. Becker, R., Shimko, R., Sementsov, G., Blyaut, Y., Girenko, S., Petesh, M., Sukach, A., Repeta, A. (2009). A method for protecting the compressor from surge, 22, 10.

    7. Slobodyan, A. V. (2007). System peredpompazhnogo Poperedjennia that viznachennya robochoї point gazoperekachuvalnogo unit type SCC-10 bazі mіkroprotsesornogo Comptroller MІK-51. Oil and Gas energy, 3, 31–34.

    8. Blyaut, J. (2008). Energy-saving technology for surge control of centrifugal pumping units booster station underground gas storage. Oil and Gas energy, 2, 33–38.

    9. Mamonov, O., Targonsky, V. (2006). Introduction of energy saving technologies in the anti-surge control blowers, 1 (37), 6–7.

    10. Lagoyda, А., Blyaut, J., Lesiv, E., Sementsov, G. (2012). Analysis of the dynamic properties of a centrifugal supercharger compressor turbine drive as control object. Oil and Gas energy, 2 (18), 72–85.

    11. Olejnikov, V. (1968). Collection of problems and examples in the theory of automatic control (optimal, extreme and software management). High School, 200.

    12. Zaitsev, G. (1989). Automatic Control Theory and regulirovaniya. High School, 431.

    13. Blyaut, J. (2013). Automatic identification of the characteristics of a surge of gas pumping units with gas turbine drive for effective surge control, 20.

Published

2014-10-21

How to Cite

Семенцов, Г. Н., & Лагойда, А. І. (2014). Determination of optimal transient in the anti-surge control system of the gas compressor unit. Eastern-European Journal of Enterprise Technologies, 5(8(71), 26–30. https://doi.org/10.15587/1729-4061.2014.27793

Issue

Section

Energy-saving technologies and equipment