Liquid jet cooler-based liquid hydrogen fueling and thermostating launch system development
DOI:
https://doi.org/10.15587/1729-4061.2016.85456Keywords:
liquid hydrogen, starting complex, evaporative cooling, jet liquid coolerAbstract
A variant of modernization is examined of the ground-based system for filling and thermostating by liquid hydrogen of fuel tank of superheavy carrier rocket (CR) “Energy” by using, instead of traditional surface heat exchangers, a jet liquid cooler.
The filling systems that are in operation at present imply the filling of CR tanks with cryogenic components in the boiling state, which limits the period when a rocket is positioned in the launching pad. But the system that was created in the USSR way back in 1987 made it possible to fill the CR “Energy” fuel tanks with the components of rocket propellant in the supercooled state with subsequent thermostating of tanks. Filling the CR tanks with components in the supercooled state with heightened density provided for an increase in the mass of payload by 5 % and allowed prolonging the period, which would rather be used for eliminating the malfunctions in preparing CR for launch, without returning the components to the filling tanks. They used as heat exchange devices the heat exchanger-recuperators of the “boiling bath” type. In this case, the semiclosed scheme of the cryogenic component circulation was implemented.
Using a compact jet liquid cooler as the heat exchange device makes it possible to eliminate bulky heat exchangers, as well as simplify the system through transition to the closed scheme of liquid hydrogen circulation while thermostating the CR fuel tank. Thus, the cryo-component saving is provided for in the process of cooling the structure elements in preparing for the filling.
The procedure for calculating the process of thermostating a fuel tank based on the jet liquid cooler was developed for solving the task of modernization of the filling and thermostating system, which allowed us to calculate attainable parameters of the thermostating system and to determine the range of system working ability. The outlet of external heat flows with power to 1 MW is ensured at pressure at the JCL nozzle exit section 10–30 kPa and temperature of “hot” parahydrogen removal from the tank 18–20 K. In particular, the 73 % increase in the operation period of the system during standard system filling with liquid hydrogen or the savings in liquid hydrogen at the estimated time of CR launch might be regarded as the result of using the modernized filling and thermostating system.
The technical solutions proposed may be applied when designing new and modernizing those existing systems of storage, cooling and filling with liquid hydrogen of the carrier rockets fuel tanks, including promising objects of heavy and superheavy CRs: SLS and Falkon Heavy (USA), CZ-5 and CZ-9 (C.P.R), Angara 5V (Russian Federation).References
- Gorbatskii, Yu. V., Domashenko, A. M., Krishtal, V. N. (2002). Stages of development of cryogenic systems for space rocket technology. Chemical and Petroleum Engineering, 38 (9/10), 594–598. doi: 10.1023/a:1022024923524
- Krishtal, V. N., Lenskii, A. B. (2008). Kriogennye zapravochnye sistemy mnogorazovogo kosmicheskogo kompleksa "Jenergija-Buran". Tekhnicheskie Gazy, 6, 13–20.
- Domashenko, A. M., Krishtal, V. N., Krasovickij, M. V., Krasovickij, Ju. V., Lapshin, A. G. (2009) Sozdanie i sovershenstvovanie kriogennyh zapravochnyh i stendovyh kompleksov raketno-kosmicheskoj tehniki. Tekhnicheskie Gazy, 1, 27–33.
- Domashenko, A. M., Krishtal, V. N. (2007) Principy postroenija, problemy i opyt sozdanija kriogennyh zapravochnyh kompleksov dlja raketno-kosmicheskoj tehniki. Al'ternativnaja jenergetika i jekologija, 9 (53), 16–19.
- Fesmire, J. E., Tomsik, T. M., Bonner, T., Oliveira, J. M., Conyers, H. J., Johnson, W. L., Notardonato, W. U. (2014) Integrated heat exchanger design for a cryogenic storage tank. Advances in Cryogenic Engineering AIP Conf. Proc. 1573, 1365–1372. doi: 10.1063/1.4860865
- Swanger, A. M., Jumper, K. M., Fesmire, J. E., Notardonato, W. U. (2015). Modification of a liquid hydrogen tank for integrated refrigeration and storage. IOP Conference Series: Materials Science and Engineering, 101, 012080. doi: 10.1088/1757-899x/101/1/012080
- Ramesh, T. (2014). Investigation studies on sub-cooling of cryogenic liquids using helium injection method. American Journal of Applied Sciences, 11 (5), 707–716. doi: 10.3844/ajassp.2014.707.716
- Ramesh, T., Thyagarajan, K. (2014) Performance Studies on Sub-cooling of Cryogenic Liquids Used for Rocket Propulsion Using Helium Bubbling International Journal of Engineering and Technology, 6 (1), 58–65.
- Petukhov, I. I., Bredikhin, V. V., Shakhov, Y. V. (1999). Jet equipment for cryogenic fuel cooling. 14th International Symposium on Air Breathing Engines.
- Petukhov, I. I., Shakhov, Y. V. (2010) Raschet staticheskih harakteristik strujnogo ohladitelja zhidkosti. Aviacionno-kosmicheskaja tehnika i tehnologija, 7 (74), 71–76.
- Sokolov, E. Ya., Zinger, N. M. (1989). Strujnye apparaty. Moscow: Energoizdat, 352.
Downloads
Published
How to Cite
Issue
Section
License
Copyright (c) 2016 Yurij Shakhov
This work is licensed under a Creative Commons Attribution 4.0 International License.
The consolidation and conditions for the transfer of copyright (identification of authorship) is carried out in the License Agreement. In particular, the authors reserve the right to the authorship of their manuscript and transfer the first publication of this work to the journal under the terms of the Creative Commons CC BY license. At the same time, they have the right to conclude on their own additional agreements concerning the non-exclusive distribution of the work in the form in which it was published by this journal, but provided that the link to the first publication of the article in this journal is preserved.
A license agreement is a document in which the author warrants that he/she owns all copyright for the work (manuscript, article, etc.).
The authors, signing the License Agreement with TECHNOLOGY CENTER PC, have all rights to the further use of their work, provided that they link to our edition in which the work was published.
According to the terms of the License Agreement, the Publisher TECHNOLOGY CENTER PC does not take away your copyrights and receives permission from the authors to use and dissemination of the publication through the world's scientific resources (own electronic resources, scientometric databases, repositories, libraries, etc.).
In the absence of a signed License Agreement or in the absence of this agreement of identifiers allowing to identify the identity of the author, the editors have no right to work with the manuscript.
It is important to remember that there is another type of agreement between authors and publishers – when copyright is transferred from the authors to the publisher. In this case, the authors lose ownership of their work and may not use it in any way.