Optimizing the process of fire detection in warehouses considering the type and location of fire detectors

Authors

DOI:

https://doi.org/10.15587/1729-4061.2022.254620

Keywords:

fire detector, fire development, fire protection system, full-factor experiment, trigger time

Abstract

An integral condition for avoiding damage due to fires in warehouses, or at least minimizing them, is the early detection of fires using fire protection systems, as well as its timely localization. Depending on which fire detectors are selected to protect the relevant premises and where they are installed, the time of operation of all elements of automatic control systems in case of a fire will depend. The review of literary data revealed that at present there is no comprehensive approach to choosing the optimal placement in warehouses. In addition, the optimal placement of fire detectors within the room, taking into consideration the type of fire load, has not been sufficiently studied. Therefore, the purpose of the current study is to establish the dependence of the time of operation of different types of fire detectors on the type of combustible material, namely its mass burnout rate, distance, and height of placement of detectors from a potential fire site. This paper reports a procedure for conducting an experimental study to identify the appropriate dependence for warehouses. The results of the experiments showed that the most effective in warehouses are targeted fire smoke detectors and aspiration systems. Based on the results of a complete factor experiment, nonlinear empirical dependences to determine the time of operation of smoke fire detectors on the above factors were built. The resulting empirical dependences make it possible to choose fire detectors and optimally place them within a room. The average error in these dependences when compared with the experimental data is 6.9 %. The use of the derived dependences makes it possible to reduce the time of operation of fire detectors by 14 s in comparison with their placement in accordance with building codes

Author Biographies

Volodymyr Sharyy, Lviv State University of Life Safety

Adjunct

Department of Fire Tactics and Emergency Rescue Operations

Ivan Pasnak, Lviv State University of Life Safety

PhD, Associate Professor

Institute of Fire and Technogenic Safety

Artur Renkas, Lviv State University of Life Safety

PhD

Department of Operation of Vehicles and Fire Rescue Equipment

References

  1. DBN V.2.5-56:2014. Systemy protypozhezhnoho zakhystu. Available at: http://kbu.org.ua/assets/app/documents/dbn2/98.1.%20ДБН%20В.2.5-56~2014.%20Системи%20протипожежного%20захисту.pdf
  2. Hulida, E., Pasnak, I., Renkas, A., Sharyy, V. (2020). Engineering method for determining rational fire protection parameters of warehouses. Eastern-European Journal of Enterprise Technologies, 2 (10 (104)), 38–45. doi: https://doi.org/10.15587/1729-4061.2020.201819
  3. Nan, C., Xianmeng, M., Wenhui, D. (2012). Experimental Study on the Testing Environment Improvement of Fire Smoke Detectors. Procedia Engineering, 45, 610–616. doi: https://doi.org/10.1016/j.proeng.2012.08.211
  4. Kruell, W., Schultze, T., Tobera, R., Willms, I. (2013). Analysis of Dust Properties to Solve the Complex Problem of Non-fire Sensitivity Testing of Optical Smoke Detectors. Procedia Engineering, 62, 859–867. doi: https://doi.org/10.1016/j.proeng.2013.08.136
  5. Zhang, W., Olenick, S. M., Klassen, M. S., Carpenter, D. J., Roby, R. J., Torero, J. L. (2008). A smoke detector activation algorithm for large eddy simulation fire modeling. Fire Safety Journal, 43 (2), 96–107. doi: https://doi.org/10.1016/j.firesaf.2007.05.004
  6. Liu, F., Zhao, Z., Yao, H., Liang, D. (2013). Application of Aspirating Smoke Detectors at the Fire Earliest Stage. Procedia Engineering, 52, 671–675. doi: https://doi.org/10.1016/j.proeng.2013.02.204
  7. Choi, M.-S., Lee, K.-O. (2018). Study on Influence of Air Flow of Ceiling Type Air Conditioner on Fire Detector Response. Fire Science and Engineering, 32 (5), 40–45. doi: https://doi.org/10.7731/kifse.2018.32.5.040
  8. Zheng, W., Zhang, X., Wang, Z. (2016). Experiment Study of Performances of Fire Detection and Fire Extinguishing Systems in a Subway Train. Procedia Engineering, 135, 393–402. doi: https://doi.org/10.1016/j.proeng.2016.01.147
  9. Ko, E. Y., Hong, S.-H., & Cha, J. (2020). A Study on Remote IoT operating time for Fire Detector of Smart Home. The Journal of the Institute of Internet, Broadcasting and Communication, 20 (2), 235–238. doi: https://doi.org/10.7236/JIIBC.2020.20.2.235
  10. Liu, X., Hou, D., Ji, J., Zhu, H. (2021). Experiment and numerical simulation of cable trench fire detection. Case Studies in Thermal Engineering, 28, 101338. doi: https://doi.org/10.1016/j.csite.2021.101338
  11. Hong, S.-H. (2016). An Experimental Study on the Response Characteristics of Fire Detector for Early Stage Fire Detection in Warehouse. Fire Science and Engineering, 30 (3), 41–47. doi: https://doi.org/10.7731/kifse.2016.30.3.041

Downloads

Published

2022-04-30

How to Cite

Sharyy, V., Pasnak, I., & Renkas, A. (2022). Optimizing the process of fire detection in warehouses considering the type and location of fire detectors . Eastern-European Journal of Enterprise Technologies, 2(10 (116), 66–73. https://doi.org/10.15587/1729-4061.2022.254620