Synthesis of the system for minimizing losses in asynchronous motor with a function for current symmetrization
DOI:
https://doi.org/10.15587/1729-4061.2017.108545Keywords:
asynchronous motor, thyristor converter, electric drive, loss minimization, voltage asymmetry, symmetrizationAbstract
The operation modes of the TVC-AM electric drive in which the power losses can be reduced were mathematically described. It was defined more precisely that what was at issue is the continued operation of an asynchronous motor at artificial characteristics in the region of nominal slip with an energetics better than at the working section of the natural mechanical characteristic. The system of automatic minimization of power losses of asynchronous motors was developed. It was shown that under conditions of feeding the electric drive from a source with asymmetrical voltage, it is necessary to use phase-by-phase control which requires the use of three control channels and three feedback channels. The logic of the feedback action is that when the load on the AM shaft decreases, it reduces the output voltage of the TVC and the motor currents. As a consequence, it becomes possible to maintain equality of the load angles of all phases to the optimum value. This makes it possible to solve the problem of minimizing the AM losses in a case of equality of the load angles to the optimal value and symmetrization due to equality of load angles by the phases of the motor. The quantitative indices of power loss decrease as well as the symmetrization indices when the electric drive is powered from a source with an asymmetric voltage were shown. The features of the power loss minimization system and the ways of improvement of its efficiency were illustrated. It was shown that the use of the proposed control system led to an improvement in both the power and dynamic parameters of the asynchronous electric drive. A 5 to 45 % reduction of power losses in the range of operating moments of 0£М£Мbo relative to losses during operation at the main mechanical characteristic was recorded. The symmetrization effect was characterized by a 1.5 to 6 times reduction of the current asymmetry coefficients.
The use of a thyristor voltage converter makes it possible to realize controlled transient start-up and braking modes. Symmetrization of the acting currents of the asynchronous motor results in an 80–150 % reduction of vibrational components of the electromagnetic moment in a steady-state regimeReferences
- Liang, X., Ilochonwu, O. (2011). Induction Motor Starting in Practical Industrial Applications. IEEE Transactions on Industry Applications, 47 (1), 271–280. doi: 10.1109/icps.2010.5489897
- Babakin, V. I. (2007). Avtomatizirovannyi elektroprivod tipovyh proizvodstvennyh mekhanizmov i tekhnologicheskih kompleksov. Ufa: UGNTU, 224.
- Gui-xi, J., Hong-jun, S. (2009). Research on Intelligent Soft Starter of Asynchronous Electromotor. 2009 WRI Global Congress on Intelligent Systems. doi: 10.1109/gcis.2009.104
- Boyko, A. A. (2014). Analiz vozmozhnosti ekonomyi energyi potreblyaemoy liftovymi lebedkami pri primenenyi tiristornyh preobrazovateley napryazheniya. Pidiomno-transportna tekhnika, 3 (43), 54–63.
- Tremlin, R. (2006). Soft–Start drives. Wire Ind, 626, 92–96.
- Tunyasrirut, S., Wangsilabatra, B., Suksri, T. (2010). Phase control thyristor based soft-starter for a grid connected induction generator for wind turbine system. Control Automation and Systems (ICCAS), International Conference. Available at: http://ieeexplore.ieee.org/document/5669944/
- Yeh, C.-C., Demerdash, N. A. O. (2009). Fault-Tolerant Soft Starter Control of Induction Motors With Reduced Transient Torque Pulsations. IEEE Transactions on Energy Conversion, 24 (4), 848–859. doi: 10.1109/tec.2009.2025340
- Braslavskij, I., Zyuzev, A., Nesterov, K. (2008). Thyristor controlled asynchronous electrical drive without speed sensor. 2008 International Symposium on Power Electronics, Electrical Drives, Automation and Motion. doi: 10.1109/speedham.2008.4581098
- Lyutarevich, A. G., Goryunov, V. N., Dolinger, S. Yu., Hatsevskiy, K. V. (2013). Voprosy modelirovaniya ustroystv obespecheniya kachestva elektricheskoy energyi. Omskiy nauchnyy vestnik, 1 (117), 168–173.
- Pinchuk, O. G. (2008). Energeticheskie pokazateli asinhronnogo dvigatelya pri razlichnyh parametrah nessimetryi pitayushchego napryazheniya. Elektrotekhnika i enerhetyka. Naukovi pratsi DonNTU, 8 (140), 201–205.
- Zhang, P., Du, Y., Habetler, T. G., Lu, B. (2012). A Nonintrusive Winding Heating Method for Induction Motor Using Soft Starter for Preventing Moisture Condensation. IEEE Transactions on Industry Applications, 48 (1), 117–123. doi: 10.1109/tia.2011.2175875
- Boyko, A. A., Budashko, V. V., Yushkov, E. A., Boyko, N. A. (2016). Synthesis and research of automatic balancing system of voltage converter fed induction motor currents. Eastern-European Journal of Enterprise Technologies, 1 (2 (79)), 22–34. doi: 10.15587/1729-4061.2016.60544
- Boyko, A. O., Beresan, A. A. (2010). Modelirovanie sistemy TPN-AD. Matematicheskoe modelirovanie, 39–42.
- Mityashin, N. P., Derunov, V. A., Aref'ev, L. Yu. (2005). Modeli chuvstvitel'nosti fazovyh napryazheniy k izmeneniyu upravlyayushchih vozdeystviy sistemy simmetrirovaniya napryazheniy avtonomnoy seti. Problemy energetiki, 99–106.
- Petrov, L. P., Andryushchenko, O. A., Kapinos, V. I. et. al. (2000). Tiristornye preobrazovateli napryazheniya dlya asinhronnogo elektroprivoda. Moscow: Energoatomizdat, 200.
- Prado, A., Kurokawa, S., Bovolato, L., Filho, J. (2011). Phase-Mode Transformation Matrix Application for Transmission Line and Electromagnetic Transient Analyses. New York: Nova Science Pub Inc, 40.
- Kravchik, A. E., Shlaf, M. M., Afonin, V. I. (1982). Asinhronnye dvigateli serii 4A. Moscow: Energoizdat, 504.
Downloads
Published
How to Cite
Issue
Section
License
Copyright (c) 2017 Andrew Boyko, Yana Volyanskaya
This work is licensed under a Creative Commons Attribution 4.0 International License.
The consolidation and conditions for the transfer of copyright (identification of authorship) is carried out in the License Agreement. In particular, the authors reserve the right to the authorship of their manuscript and transfer the first publication of this work to the journal under the terms of the Creative Commons CC BY license. At the same time, they have the right to conclude on their own additional agreements concerning the non-exclusive distribution of the work in the form in which it was published by this journal, but provided that the link to the first publication of the article in this journal is preserved.
A license agreement is a document in which the author warrants that he/she owns all copyright for the work (manuscript, article, etc.).
The authors, signing the License Agreement with TECHNOLOGY CENTER PC, have all rights to the further use of their work, provided that they link to our edition in which the work was published.
According to the terms of the License Agreement, the Publisher TECHNOLOGY CENTER PC does not take away your copyrights and receives permission from the authors to use and dissemination of the publication through the world's scientific resources (own electronic resources, scientometric databases, repositories, libraries, etc.).
In the absence of a signed License Agreement or in the absence of this agreement of identifiers allowing to identify the identity of the author, the editors have no right to work with the manuscript.
It is important to remember that there is another type of agreement between authors and publishers – when copyright is transferred from the authors to the publisher. In this case, the authors lose ownership of their work and may not use it in any way.