An experimental analysis of DC magnetic blowout high-speed circuit breakers’ parameters

Authors

DOI:

https://doi.org/10.15587/1729-4061.2020.210232

Keywords:

high-speed circuit breaker, breaking time, arcing time, arc voltage

Abstract

High-speed circuit breakers (HSCB) used in DC circuits are one of the basic elements of overload, short-circuit and electric shock protection. Such breakers are used in transport (trams, trolleybuses, subways and railways) in electric power supply facilities and in vehicles. The performance and capability of limiting the current depend on the HSCB design and solutions applied in it. The circuit parameters, particularly its inductance also affect the performance. Additionally, each DC breaking in the RL circuit is accompanied by overvoltages whose level depends on the circuit parameters and breaker design. The paper discussed the process of direct current breaking by magnetic blowout high-speed circuit breakers and factors that affect the HSCB performance, i. e. opening time and arcing time. The influence of the circuit parameters and HSCB design on the value of arc voltage is outlined. The results of laboratory tests of 4 types of high-speed circuit breakers produced in Europe are presented. The test results were used to analyze the effect of current changes in the short circuit on the time of current breaking and the value of switching overvoltages – arc voltage. The results of simulation of the short-circuit breaking in the RL DC circuit made at the rate-of-rise of current in the circuit are presented. Based on the tests and simulations, the current breaking times, values of arc voltage generated in this process and arc energy that is acquired and dissipated by the arc chamber are determined. The objective of the tests and simulations was to answer the question whether it is possible to turn off direct current quickly without generating high arc voltage values – overvoltages in the circuit and how di/dt changes should be formed by a high-speed circuit breaker to achieve the shortest possible time with the lowest possible arc voltage and its lowest energy

Author Biography

Artur Rojek, Railway Research Institute Chlopickiego str., 50, Warsaw, Poland, 04-

Doctor of Technical Sciences, Head of Division

Electrical Power Division

References

  1. Ahmad, M., Wang, Z. (2019). A Hybrid DC Circuit Breaker with Fault-Current-Limiting Capability for VSC-HVDC Transmission System. Energies, 12 (12), 2388. doi: https://doi.org/10.3390/en12122388
  2. Alferov, D., Budovsky, A., Evsin, D., Ivanov, V., Sidorov, V., Yagnov, V. (2008). DC vacuum circuit-breaker. 2008 23rd International Symposium on Discharges and Electrical Insulation in Vacuum. doi: https://doi.org/10.1109/deiv.2008.4676747
  3. Bingjian, Y., Yang, G., Xiaoguang, W., Zhiyuan, H., Longlong, C., Yunhai, S. (2015). A hybrid circuit breaker for DC-application. 2015 IEEE First International Conference on DC Microgrids (ICDCM). doi: https://doi.org/10.1109/icdcm.2015.7152036
  4. Borkowski, P., Nowak, Ł., Szymański, S. (2018). The new design of the vacuum circuit breaker mounted on the roof of Electric Traction Units. PRZEGLĄD ELEKTROTECHNICZNY, 1 (8), 136–139. doi: https://doi.org/10.15199/48.2018.08.32
  5. Kowalak, R. (2007). Influence of short-circuits switched-off by current-limiting circuit breakers on MV network supplying the traction substations. Electrical Review, 83 (3), 19–22.
  6. Ma, R., Rong, M., Yang, F., Wu, Y., Sun, H., Yuan, D. et. al. (2013). Investigation on Arc Behavior During Arc Motion in Air DC Circuit Breaker. IEEE Transactions on Plasma Science, 41 (9), 2551–2560. doi: https://doi.org/10.1109/tps.2013.2273832
  7. Maciołek, T., Mierzejewski, L., Szeląg, A. (2001). Breaking the short-circuits in DC traction by high-speed circuits breakers and power-switch. Technika Transportu Szynowego, 3, 40–47.
  8. Mierzejewski, L., Szeląg, A. (1999). Research of short circuits and overvoltages in DC electric traction circuits with single-stage transformations110/3 kV. IVth International Conference MET’99, 58–64.
  9. Pei, X., Smith, A. C., Cwikowski, O., Barnes, M. (2020). Hybrid DC circuit breaker with coupled inductor for automatic current commutation. International Journal of Electrical Power & Energy Systems, 120, 106004. doi: https://doi.org/10.1016/j.ijepes.2020.106004
  10. Rojek, A, Zbieć, A. (2012). Co-ordination of Short Circuit Protection Devices in Motive Power Unit - Sub-station System. Problemy Kolejnictwa, 154, 27–46.
  11. Rojek, A. (2015). Switching-off time of electromagnetic blow-out high-speed DC circuit breaker. Problemy Kolejnictwa, 169, 53–60.
  12. Rojek, A. (2018). Parameters of DC high-speed circuit-breakers. MATEC Web of Conferences, 180, 06006. doi: https://doi.org/10.1051/matecconf/201818006006
  13. Rojek, A. (2020). Investigation of the impact of the contact arc time on the breaking time of high-speed circuit breakers. Prace Instytutu Kolejnictwa, 164, 28–41.
  14. Rojek, A., Skrzyniarz, M. (2019). Contact arc time – important parameter of DC high-speed circuit-breakers. MATEC Web of Conferences, 294, 05002. doi: https://doi.org/10.1051/matecconf/201929405002
  15. Sécheron, S. A. (2019). High-speed DC circuit breakers for fixed intallations (EN/IEC) Type UR. Available at: https://www.secheron.com/wp-content/uploads/docs/SG101001BEN_F15_Brochure_Circuit-breaker-DC_UR26-80S_09.19.pdf
  16. Szeląg, A., Tuliński, K. (2003). Analysis of technical effectiveness of application of a thyristor short-circuiting device in parallel with inductance in rectifier traction substations – simulations and measurements. VIth International Conference „Modern Electric Traction in Integrated XXI Century Europe” MET 2003.
  17. Wójcik, F. (2011). Influence of short-circuit parameters and construction of commutation circuit of ultra-high-speed vacuum circuit breakers on dynamics of its operation. Electrical Review, 87 (11), 201–208.
  18. Xingguang, H., Hua, L., Zhiquan, S., Zhigang, R., Shusheng, W., Cunwen, T., Peng, F. (2020). Concept design of 100 kA hybrid DC breaker on China fusion engineering test reactor. Fusion Engineering and Design, 158, 111740. doi: https://doi.org/10.1016/j.fusengdes.2020.111740
  19. Żukowski, P., Kozak, C. (2010). Testing dc arc energy depending on the polarity of contacts connection. Mechanizacja i Automatyzacja Górnictwa, 48 (7), 137–140.

Downloads

Published

2020-08-31

How to Cite

Rojek, A. (2020). An experimental analysis of DC magnetic blowout high-speed circuit breakers’ parameters. Eastern-European Journal of Enterprise Technologies, 4(5 (106), 35–40. https://doi.org/10.15587/1729-4061.2020.210232

Issue

Section

Applied physics